Anteenada ASU fiber optic cable
Fiilada fiber optic ASU ee ay bixiso GDTX waxaa loo qaabeeyey, la soo saaray oo la tijaabiyey iyadoo la raacayo heerarka sida soo socota:
ITU-T G.652.D | Astaamaha fiber indhaha ee hal-hab ah |
IEC 60794-1-1 | Fiber Optical-Qaybta 2: Tilmaamaha Guud-Guud |
IEC 60794-1-21 | Xadhkaha fiilooyinka indhaha-qayb 1-21-Qeexitaan guud-Nidaamka tijaabada fiilada indhaha ee aasaasiga ah-hababka tijaabada makaanikada |
IEC 60794-1-22 | Xadhkaha fiilooyinka indhaha-qayb 1-22-Qeexitaan guud-Nidaamka tijaabada fiilada indhaha ee aasaasiga ah-Qaabka tijaabada deegaanka |
IEC 60794-4-20 | Xadhkaha fiilooyinka indhaha-Qaybta 3-10: Xadhkaha dibadda - Qaddaynta qoyska ee fiilooyinka isgaadhsiinta hawada iskood |
IEC 60794-4 | Xadhkaha fibre-aragga-Qaybta 4: Qeexitaan qaybeed-Xadhkaha anteenada indhaha ee ay weheliyaan khadka korantada |
Xadhkaha fiilooyinka indhaha ee la keeno si waafaqsan tilmaamahan ayaa awood u leh inay u adkeystaan xaaladda adeegga caadiga ah muddo shan iyo labaatan (25) sano ah iyada oo aan waxyeello loo geysan sifooyinka hawlgalka fiilada.
Shayga | Qiimaha |
heerkulka hawlgalka | -40ºC~+60ºC |
Heerkulka rakibaadda | -20ºC~+60ºC |
Heerkulka kaydinta | -25ºC~+70ºC |
Baadhista foorarsan ee taagan | 10 jeer dhexroorka fiilada |
Radius foorarsan oo firfircoon | 20 jeer dhexroorka fiilada |
Tilmaamaha Farsamada
1.The daahan labaad ee gaarka ah iyo technology stranding waxay siinaya fiber meel ku filan iyo adkaysiga foorarsan, kaas oo hubiya hantida indhaha wanaagsan ee fiber ee fiilada.
2.Xakamaynta habka saxda ah waxay hubisaa waxqabadka farsamada iyo heerkulka wanaagsan
3.Waxyaabaha ceeriin ee tayada sare leh ayaa dammaanad qaadaya nolosha adeegga dheer ee fiilada
Qeybta Cable-ka
Aqoonsiga Tube Fiber iyo dabacsan (TIA-EIA 598-B)
Dhismaha iyo Alaabta Halbeegga ah | Sharaxaada | ||
Fiber indhaha (G.652D) | MFD(1310nm)9.2±0.4um Midabaysan:1310nm:≤0.35dB/km; 1550nm:≤0.22dB/km; | ||
6F | 12F | ||
Tuubo dabacsan | Fiber tuubo kasta | 6 | 12 |
Midabka Fiber | Koodhka Midabka Fiber | ||
Dhexroorka(±01mmmm) | 2.0 | 2.0 | |
Midabka Tube | Dabiiciga ah | Dabiiciga ah | |
Xubinta xoogga | cabbirka±005mm) | 2.0mmFRP*2 | 2.0mmFRP*2 |
Walxaha xannibaya biyaha | dunta biyaha xirta | ||
Galka dibadda | Qalab | Madow PE | |
Dhumucda(±02mm) | Magac ahaan: 1.2mm | ||
Xadhiga jeexjeex | Casaan 1pcs2000D | ||
Dhexroorka magaca fiilada (mm) | 6.6 | 6.6 | |
Cabbirka qiyaastii. miisaanka (±3kg/km) | 42 | 42 | |
Luqadda ugu yar | Firfircoon | 20waqtiyada dhexroorka fiilada | |
Kala duwanaanta heerkulka | Hawlgalka | -10℃+60℃ | |
XIDHIIDHKA | Dhererka | 3KM/DURUM | |
Cabbirka | Dhumucda xaashida duubka ah 1.5MM:OD*W= 780*550mm (ku dar xaashida duubka) | ||
Tijaabi xoogga xajinta | Muddada gaaban iyo muddada dheer | 1 daq,1000N/400N @1550nm Dulmiga Fiber <0.3% Dhiirigelin dheeraad ah≤0.1dB | |
Burburi | 1min 1000N @1550nm Dheeraad ah≤0.1dB | ||
Daabac | Nooca calaamadaynta | Calaamadaynta khad Jet | |
Tijaabada farsamada ugu weyn & sifooyinka deegaanka
1.Xoojinta Xoojinta IEC 794-1-E1
2.Crush Test IEC 60794-1-E3
3.Impact Test IEC 60794-1-E4
4. laablaabashada soo noqnoqda IEC 60794-1-E6
5.Torsion IEC 60794-1-E7
6.Water Gelitaanka IEC 60794-1-F5B
7. Heerkulka Baaskiilka IEC 60794-1-F1
8.Compound Flow IEC 60794-1-E14
9.Sheath High Voltage Test
Cable iyo Dhererka Calaamadaynta
Galka waa in lagu calaamadiyaa xarfo cad oo u dhexeeya hal mitir oo soo socda
xog. Calaamadayn kale ayaa sidoo kale la heli karaa haddii uu codsado macmiilka.
1) Magaca wax-soo-saarka: GDTX
1) Sannadka soo saaraha: 2022
2) NOOCA CABALKA: ADSS 100M SPAN
3) Nooca Fiber iyo tirinta: 24G652D
4) Calaamadaynta dhererka ee hal mitir u dhexeeya: tusaale: 0001 m, 0002m.
Dhererka Gariiradda
Dhererka gariiradda caadiga ah: 2/3/4 km/reel, dherer kale ayaa sidoo kale la heli karaa.
Xiritaanka Cable
Labada daraf ee fiilada waxaa lagu xiri doonaa koofiyadaha caagagga ah ee ku habboon si looga hortago gelitaanka qoyaanka inta lagu jiro dhoofinta, maaraynta iyo kaydinta. Dhamaadka gudaha ayaa diyaar u ah baaritaanka.